99,997% reduktion av levande SARS-CoV-2-virus på 30 minuter

2022-01-28T10:58:10+01:00

SARS-CoV-2 Reduction AUTHORS Dr. Dana Yee M.D, Clinical Pathologist and Medical Director; Sam Kabbani, MS, BS, MT(ASCP), CLS, Chief Scientific Officer; Albert Brockman, Chief Biosafety Officer; Kevin Noble, Chief Operating Officer. FACILITY Innovative Bioanalysis, Inc. DOWNLOAD Full Report Objective To evaluate the efficacy of the Defend 1050 [...]

99,997% reduktion av levande SARS-CoV-2-virus på 30 minuter2022-01-28T10:58:10+01:00

VOC Reduction

2020-09-30T20:18:17+02:00

VOC Reduction AUTHORSRobin Svedlind and Filip SandbergFACILITYCamfil Laboratories – Tech Center DOWNLOAD Full Report ObjectiveTo evaluate the particulate and molecular efficiency of the NV1050 in a test chamber using a VOC.  MethodologyTest method: CADRA typical aromatic VOC was generated in the laskin nozzle and injected into a room until a pre-set [...]

VOC Reduction2020-09-30T20:18:17+02:00

Staphylococcus epidermidis Bacteria Reduction

2020-09-30T20:17:05+02:00

Staphylococcus epidermidis Bacteria Reduction AUTHORSR. WormaldFACILITYUniversity of Huddersfield DOWNLOAD Full Report ObjectiveTo evaluate the efficacy of the NV800 in reducing Staphylococcus epidermidis aerosols, a surrogate for methicillin-resistant Staphylococcus aureus (MRSA).MethodologyA 1.0 m3 air tight perspex chamber was used to evaluate the ability of the NV800 to remove Staphylococcus epidermidis aerosols. The chamber was fitted with an internal fan [...]

Staphylococcus epidermidis Bacteria Reduction2020-09-30T20:17:05+02:00

Staphylococcus epidermidis and Aspergillus niger Reduction

2020-09-30T20:15:58+02:00

Staphylococcus epidermidis and Aspergillus niger Reduction AUTHORSRomero-Mangado et al.FACILITYNASA Ames Research Center DOWNLOAD Full Report ObjectiveTo explore the efficacy of the atmospheric pressure dielectric barrier discharge (DBD) technology on inactivating airborne pathogens, specifically Staphylococcus epidermidis, a surrogate for methicillin-resistant Staphylococcus aureus (MRSA) and Aspergillus niger.MethodologyThe NV200 was placed inside a biosafety cabinet, and a nebulizer [...]

Staphylococcus epidermidis and Aspergillus niger Reduction2020-09-30T20:15:58+02:00

Staphylococcus epidermidis Bacteria Reduction

2020-09-30T20:12:25+02:00

Staphylococcus epidermidis Bacteria Reduction AUTHORSJessica Dobbin, BSc BAFACILITYNovaerus Research and Development Labs DOWNLOAD Full Report ObjectiveTo evaluate the efficacy of the NV1050 in reducing airborne Staphylococcus epidermidis bacteria, a surrogate for methicillin-resistant Staphylococcus aureus (MRSA).MethodologyThe test environment was a 30 m3 test chamber, located in the Novaerus microbiology laboratory. During the testing, the NV1050 device was [...]

Staphylococcus epidermidis Bacteria Reduction2020-09-30T20:12:25+02:00

Staphylococcus epidermidis Bacteria Reduction

2020-09-30T20:10:36+02:00

Staphylococcus epidermidis Bacteria Reduction AUTHORSPark Seo-Hyun and Jeon, Yong- Woo, Technical ManagerFACILITYKorea Testing Laboratory DOWNLOAD Full Report ObjectiveTo assess the performance of the NV1050 in reducing Staphylococcus epidermidis bacteria.MethodologyTest Method: KOUVA AS02: 2019Bacteria: Staphylococcus epidermidis (ATCC 12228)Temperature: (23 +/- 2) °CHumidity: (50 +/- 5) % R.H.Test time: 1 hourTest chamber: 60m3Air flow: MaximumSummary of ResultsThe [...]

Staphylococcus epidermidis Bacteria Reduction2020-09-30T20:10:36+02:00

Methicillin-resistant Staphylococcus aureus (MRSA) Reduction

2020-11-11T11:04:19+01:00

Methicillin-resistant Staphylococcus aureus (MRSA) Reduction AUTHORS Travis R. Farley, Study Director FACILITY Microbac Laboratories, Inc. DOWNLOAD Full Report ObjectiveTo evaluate the efficacy of the NV900 on reducing methicillin-resistant Staphylococcus aureus (MRSA).MethodologyThe challenge bacteria were aerosolized using a six-jet collision nebulizer under high pressure air and introduced into the chamber with the NV900.Summary [...]

Methicillin-resistant Staphylococcus aureus (MRSA) Reduction2020-11-11T11:04:19+01:00

Phi X 174 Virus Reduction

2020-09-30T20:06:44+02:00

Phi X 174 Virus Reduction AUTHORSPark Seo-Hyun and Jeon, Yong- Woo, Technical ManagerFACILITYKorea Testing Laboratory DOWNLOAD Full Report ObjectiveTo assess the performance of the NV1050 in reducing phi X 174 virus.MethodologyTest Method: KOUVA AS02: 2019Virus: Phi-X174 (ATCC 13706-B1)Temperature: (23 +/- 2) °CHumidity: (50 +/- 5) % R.H.Test time: 30 minutesTest chamber: [...]

Phi X 174 Virus Reduction2020-09-30T20:06:44+02:00

Particle Reduction

2020-09-30T20:05:30+02:00

Particle Reduction AUTHORSRobin Svedlind and Filip SandbergFACILITYCamfil Laboratories – Tech Center DOWNLOAD Full Report ObjectiveTo evaluate the particulate and molecular efficiency of the NV1050 in a test chamber using DEHS.MethodologyTest method: CADRDEHS was generated in the laskin nozzle and injected into a room until a pre-set concentration was achieved then the [...]

Particle Reduction2020-09-30T20:05:30+02:00

Nitrogen Dioxide Reduction

2020-09-30T20:04:20+02:00

Nitrogen Dioxide Reduction AUTHORSJamie Balarashti, Dan Merchant, Zach ConleyFACILITYAerosol Research and Engineering Laboratories DOWNLOAD Full Report BackgroundThis in vitro study characterized the removal efficacy of Nitrogen Dioxide (NO2) by the Novaerus NV1050 system. Novaerus’s NV1050 system is designed to eliminate harmful gases in order to purify rooms and create safe environments [...]

Nitrogen Dioxide Reduction2020-09-30T20:04:20+02:00